U.S. Energy Information Administration logo
Skip to sub-navigation

Electricity

Form EIA-860 detailed data with previous form data (EIA-860A/860B)

The survey Form EIA-860 collects generator-level specific information about existing and planned generators and associated environmental equipment at electric power plants with 1 megawatt or greater of combined nameplate capacity. Summary level data can be found in the Electric Power Annual.

Starting with 2013 data, the EIA-860 began collecting construction cost data for new electric generators. Aggregated average construction cost information can be found on the Construction cost data for electric generators page.

Detailed data are compressed (zip) and contain the following files:

  • LayoutYyyyy– Provides a directory of all (published) data elements collected on the Form EIA-860 together with the related description, specific file location(s), and, where appropriate, an explanation of codes.
  • 1___UtilityYyyyy - Contains utility-level data for the plants and generators surveyed in the reporting year.
  • 2___PlantYyyyy - Contains plant-level data for the generators surveyed in all available years.
  • 3_1_GeneratorYyyyy – Contains generator-level data for the surveyed generators, split into three tabs.
    • The Operable tab includes those generators which are currently operating, out of service or on standby;
    • The Proposed tab includes those generators which are planned and not yet in operation; and
    • The Retired and Canceled tab includes those generators which were cancelled prior to completion and operation and retired generators at existing plants.
    • The retired tab only includes those retired generators which were reported in the most current data cycle. This is not a comprehensive list. Starting with March 2017 data, Preliminary Monthly Electric Generator Inventory includes a comprehensive list of generators which retired since 2002. The list can be found on the Retired tab of the data file.
  • 3_2_WindYyyyy – Contains additional details for surveyed generators that use wind as an energy source, split into two tabs:
    • The Operable tab includes those generators which are currently operating, out of service or on standby; and
    • The Retired and Canceled tab includes those generators which were cancelled prior to completion and operation and retired generators at existing plants.
  • 3_3_SolarYyyyy - Contains additional details for surveyed generators that use solar as an energy source, split into two tabs:
    • The Operable tab includes those generators which are currently operating, out of service or on standby;
    • The Retired and Canceled tab includes those generators which were cancelled prior to completion and operation and retired generators at existing plants.
  • 3_4_Energy_StorageYyyyy – Contains additional details of surveyed generators for the energy storage technology, split into two tabs:
    • The Operable tab includes those generators which are currently operating, out of service or on standby;
    • The Retired and Canceled tab includes those generators which were cancelled prior to completion and operation and retired generators at existing plants.
  • 3_5_MultiFuelYyyyy – Contains data on fuel-switching and the use of multiple fuels by surveyed generators, split into three tabs:
    • The Operable tab includes those generators which are currently operating, out of service or on standby; and
    • The Proposed tab includes those generators which are planned and not yet in operation; and
    • The Retired and Canceled tab includes those generators which were cancelled prior to completion and operation and retired generators at existing plants.
  • 4___OwnerYyyyy – Contains owner and/or operator data for generators with shared ownership and generators that are wholly-owned by an entity other than the operator (generators not appearing in the file are wholly-owned by their operator).
  • 6_1_EnviroAssocYyyyy – Contains boiler association data for the environmental equipment data collected on the Form EIA-860.
    • The Boiler Generator identifies which boilers are associated with each generator;
    • The Boiler Cooling tab shows which cooling systems are associated with each boiler;
    • The Boiler Particulate Matter tab shows which flue gas particulate (FGP) collectors are associated with each boiler;
    • The Boiler SO2 tab shows which flue gas desulfurization (FGD) systems are associated with each boiler
    • The Boiler NOx tab shows which nitrogen oxide control equipment is associated with each boiler;
    • The Boiler Mercury tab shows which mercury control equipment is associated with each boiler
    • The Boiler Stack Flue tab shows which stacks and flues are associated with each boiler; and
    • The Emissions Control Equipment tab shows the operational status, in-service date, and installation costs of all the environmental equipment.
  • 6_2_EnviroEquipYyyyy – Contains environmental equipment data for the surveyed generators.
    • The Emission Standards & Strategies tab shows boiler data as collected on Schedule 6, Part B of the Form EIA-860;
    • The Boiler Info & Design Parameters tab shows boiler data as collected on Schedule 6, Part C;
    • The Cooling tab shows cooling system data as collected on Schedule 6, Part D;
    • The FGP tab shows FGP data as collected on Schedule 6, Part E;
    • The FGD tab shows FGD data as collected on Schedule 6, Part F; and
    • The StackFlue tab shows stack and flue data as collected on Schedule 6, Part G.

 

Superseded Form EIA-860A (Utility) & B (Non-Utility) -- Retired Annual Electric Generator Report

Electric utility generator level data includes information for company, facility, unit type, prime mover, in-service date, energy source, heat content, nameplate capacity, summer and winter capability, etc.

860-A (Utility)
Data are compressed into a zip file that expands into xls data files and a txt layout file:

  • PLANTYyy - plant-level data
  • UTILYyy - utility-level data
  • TYPE3Yyy & TYPE4Yyy - 2 generator files for 1990-1997
    or GeneratorOwnershipyyyy, ProposedGeneratorsyyyy, ExistingGeneratorsyyyy - 3 generator files for 1998-2000
  • LAYOUT - ASCII layout file

860-B (Non-Utility)
Data are compressed into a zip file that expands into xls data files and a txt layout file:

  • qfdocket - qualifying data
  • xdocket - plant-level data
  • cogen - cogeneration data
  • nuppfac - non-utility power producer data
  • fuelquant - fuel quantities
  • genergy - 2 generator files
  • generator
  • noxequip - nox removal data
  • LAYOUT - ASCII layout file

 



 


Year Format
2022 ZIP
2021 ZIP
2020 ZIP
2019 ZIP
2018 ZIP
2017 ZIP
2016 ZIP
2015 ZIP
2014 ZIP
2013 ZIP
2012 ZIP
2011 ZIP
2010 ZIP
2009 ZIP
2008 ZIP
2007 ZIP
2006 ZIP
2005 ZIP
2004 ZIP
2003 ZIP
2002 ZIP
2001 ZIP

 

Superseded forms (for data prior to 2001)
    EIA-860 A (utility) and B (nonutility)

Year Utility Non-utility
2000* ZIP ZIP
1999* ZIP ZIP
1998* ZIP ZIP
1997 ZIP
1996 ZIP
1995 ZIP
1994 ZIP
1993 ZIP
1992 ZIP
1991 ZIP
1990 ZIP
* Revised February 9, 2007
Contact: Electricity data experts