File 4: Building Shell, Equipment, Energy Audits, and "Ohter" Conservation Features (cb86f04.csv) Ques- tion- naire Variable Variable Variable Variable item Description Name Position Format Building identifier BLDGID3 1- 5 Adjusted weight ADJWT3 7- 14 Variance stratum STRATUM3 16- 17 Pair member PAIR3 19- 19 Census region REGION3 21- 21 $REGION. Census division CENDIV3 23- 23 $CENDIV. B-2 Square footage SQFTC3 25- 26 $SQFTC. Principal building activity PBA3 28- 29 $ACTIVTY. D-2 Year construction was completed YRCONC3 31- 32 $YRCONC. D-4 Percent glass on exterior GLASSP3 34- 36 D-5 Percent glass on exterior GLASSPC3 38- 38 $PCTCAT. D-6 Wall construction material WLCNS3 40- 41 $WLCNS. D-7 Roof square footage category RFSQFTC3 43- 44 $RFSQFTC. D-8 Roof construction material RFCNS3 46- 47 $RFCNS. E-3a Boilers used BOILER3 49- 49 $YESNO. E-3b Furnaces that heat air used FURNAC3 51- 51 $YESNO. E-3c Heat pump (wtr source) used HTPMPW3 53- 53 $YESNO. E-3d Heat pump (air source) used HTPMPA3 55- 55 $YESNO. E-3e Central cooling used CNTLCL3 57- 57 $YESNO. E-3f Self-contained units used SLFCON3 59- 59 $YESNO. E-3g Air conditioners (walls/window) used ACWNWL3 61- 61 $YESNO. E-3h Packaged rooftop units for heat PKGHT3 63- 63 $YESNO. E-3i Packaged rooftop units for cooling PKGCL3 65- 65 $YESNO. E-3j Evaporative coolers used EVAPCL3 67- 67 $YESNO. E-3k Other heat/cooling equipment used OTHC3 69- 69 $YESNO. E-4aA Forced air through ducts used DUCT3 71- 71 $YESNO. E-4aB Forced air for heat or cooling DUCTHC3 73- 73 $HTCL. E-4bA Fan-coil units used FNCL3 75- 75 $YESNO. E-4bB Fan-coil units for heat or cooling FNCLHC3 77- 77 $HTCL. E-4cA Steam radiators/baseboards used STRADB3 79- 79 $YESNO. E-4dB Hot wtr baseboards/radiators used HWRADB3 81- 81 $YESNO. E-4eA Heating panels used PANEL3 83- 83 $YESNO. E-4fB Other distribution system OTDLV3 85- 85 $YESNO. E-4fB Other system for heat or cooling OTDHC13 87- 87 $HTCL. E-5 Tenants control heat temperature HTCNTL3 89- 89 $HTCNTL. E-5 Tenants control cooling temperature CLCNTL3 91- 91 $CLCNTL. E-6 Reduction in heat off hours RDHTOFF3 93- 93 $HTCNTL. E-6 Reduction in cooling off hours RDCLOFF3 95- 95 $CLCNTL. E-7 Space vacant for at least 3 months PORVAC3 97- 97 $YESNO. E-8 Percent vacant for at least 3 months VAC3MP3 99- 101 E-9 Reduced heat/cooling when vacant RDHCVAC3 103- 103 $YESNO. G-1 Energy audit ever performed AUDIT3 105- 105 $YESNO. G-2 Year of audit (most recent) AUDYR3 107- 108 G-2A Month of audit (if 1986) AUDMON3 110- 111 G-3A15 Regular preventive maintenance program MAINT3 113- 113 $YESNO. G-3B15 Maintenance program installed or added MNTINS3 115- 115 $INSADD. G-3C15 When maintenance program added MNTDT3 117- 117 $YRADD. G-3D15 Maintenance program due to audit MNTAUD3 119- 119 $YESNO. G-3E15 Maintenance program due to savings MNTSAV3 121- 121 $YESNO. G-3A16 Computerized energy management system HCCOMP3 123- 123 $YESNO. G-3B16 Computerized system installed or added CMPINS3 125- 125 $INSADD. G-3C16 When computerized system added CMPDT3 127- 127 $YRADD. G-3D16 Computerized system due to audit CMPAUD3 129- 129 $YESNO. G-3E16 Computerized system for $ savings CMPSAV3 131- 131 $YESNO. File 4: Building Shell, Equipment, Energy Audits, and "Other" Conservation Features (cb86f04.csv) (continued) Ques- tion- naire Variable Variable Variable Variable item Description Name Position Format G-3A17 Delamping program DELAMP3 133- 133 $YESNO. G-3B17 Delamping program installed or added DLMINS3 135- 135 $INSADD. G-3C17 When delamping program added DLMDT3 137- 137 $YRADD. G-3D17 Delamping program added due to audit DLMAUD3 139- 139 $YESNO. G-3E17 Delamping program added for $ savings DLMSAV3 141- 141 $YESNO. G-3A18 Any other energy conservation feature OTCNS3 143- 143 $YESNO. G-3A18 Type of other conservation feature OTCNSX3 145- 146 $OTCNSX. G-3B18 Other feature installed or added OTCINS3 148- 148 $INSADD. G-3C18 When other conservation feature added OTCDT3 150- 150 $YRADD. G-3D18 Other feature added due to audit OTCAUD3 152- 152 $YESNO. G-3E18 Other feature added for $ savings OTCSAV3 154- 154 $YESNO. H-1 Capability of generating electric power GENER3 156- 156 $YESNO. H-2 Primary use of generators GENUSE3 158- 159 $GENUSE. H-3 Cogeneration system COGEN3 161- 161 $YESNO. Electricity supplied ELSUPL3 163- 163 $XXSUPL. Natural gas supplied NGSUPL3 165- 165 $XXSUPL. Fuel oil supplied FKSUPL3 167- 167 $XXSUPL. Propane supplied PRSUPL3 169- 169 $XXSUPL. Steam supplied STSUPL3 171- 171 $XXSUPL. Hot water supplied HWSUPL3 173- 173 $XXSUPL.