Layout for File 10: Imputation Flags for File 3 Variable Name Variable Description Position Format PUBID7 Building identifier 1- 5 REGION7 Census region 7- 7 $REGION. CENDIV7 Census division 9- 9 $CENDIV. SQFT7 Square footage 11- 20 MISS10CH. SQFTC7 Square footage category 22- 23 $SQFTCAT. YRCONC7 Year of construction category 25- 26 $YEARCAT. PBA7 Principal building activity 28- 29 $PBA. ELUSED7 Electricity used in 1999 31- 31 $YESNO. NGUSED7 Natural gas used in 1999 33- 33 $YESNO. FKUSED7 Fuel oil used in 1999 35- 35 $YESNO. PRUSED7 Propane used in 1999 37- 37 $YESNO. STUSED7 District steam used in 1999 39- 39 $YESNO. HWUSED7 District hot water used in 1999 41- 41 $YESNO. ZFURNAC7 Imputed furnaces that heat air used 43- 43 $ZVAR. ZHTPMPH7 Imputed heat pumps used for heating 45- 45 $ZVAR. ZSLFCON7 Imputed individual space heaters used 47- 47 $ZVAR. ZSTHW7 Imputed dist steam/hot water piped in 49- 49 $ZVAR. ZBOILER7 Imputed boilers used 51- 51 $ZVAR. ZPKGHT7 Imputed packaged heating units used 53- 53 $ZVAR. ZOTHTEQ7 Imputed some other heating equip used 55- 55 $ZVAR. ZFURNP7 Imputed pct heated by furnace 57- 57 $ZVAR. ZHTPHP7 Imputed pct heated by heat pump 59- 59 $ZVAR. ZSLFCNP7 Imputed pct heated by indiv space heater 61- 61 $ZVAR. ZSTHWP7 Imputed pct heated by dist steam/hot wtr 63- 63 $ZVAR. ZBOILP7 Imputed pct heated by boiler 65- 65 $ZVAR. ZPKGHP7 Imputed pct heated by packaged heating 67- 67 $ZVAR. ZOTHTP7 Imputed pct heated by other heat equip 69- 69 $ZVAR. ZMAINHT7 Imputed main heating equipment 71- 71 $ZVAR. ZNWHTEQ7 Imputed mn ht equip replaced since 1995 73- 73 $ZVAR. ZRDHTNF7 Imputed reduce heating during off hours 75- 75 $ZVAR. ZRCAC7 Imputed central a/c used 77- 77 $ZVAR. ZHTPMPC7 Imputed heat pumps used for cooling 79- 79 $ZVAR. ZACWNWL7 Imputed individual window/wall a/c used 81- 81 $ZVAR. ZCHWT7 Imputed district chilled water piped in 83- 83 $ZVAR. ZCHILLR7 Imputed central chillers used 85- 85 $ZVAR. ZPKGCL7 Imputed packaged cooling units used 87- 87 $ZVAR. ZEVAPCL7 Imputed swamp coolers used 89- 89 $ZVAR. ZOTCLEQ7 Imputed some other equip for cooling 91- 91 $ZVAR. ZRCACP7 Imputed pct cooled by central a/c 93- 93 $ZVAR. ZHTPCP7 Imputed pct cooled by heat pump 95- 95 $ZVAR. ZACWNWP7 Imputed pct cooled by indiv room a/c 97- 97 $ZVAR. ZCHWTP7 Imputed pct cooled by district hot water 99- 99 $ZVAR. ZCHILP7 Imputed pct cooled by central chillers 101- 101 $ZVAR. ZPKGCP7 Imputed pct cooled by packaged a/c 103- 103 $ZVAR. ZEVAPP7 Imputed pct cooled by swamp coolers 105- 105 $ZVAR. ZOTCLP7 Imputed pct cooled by other cool equip 107- 107 $ZVAR. ZMAINCL7 Imputed main cooling equipment 109- 109 $ZVAR. ZNWCLEQ7 Imputed mn cl equip replaced since 1995 111- 111 $ZVAR. ZRDCLNF7 Imputed reduce cooling during off hours 113- 113 $ZVAR. ZVAV7 Imputed variable air volume (VAV) syst 115- 115 $ZVAR. ZECN7 Imputed economizer cycle 117- 117 $ZVAR. ZMAINT7 Imputed preventive maintenance program 119- 119 $ZVAR. ZEMCS7 Imputed energy mgmt and control system 121- 121 $ZVAR. ADJWT7 Adjusted weight 123- 130 PAIR7 Pair member 132- 132 STRATUM7 Variance stratum 134- 135